Skip to content
Draft for review. Not published.

Mark hold and witness points on a checklist

Some items on an inspection must not be passed over: the membrane has to be cured before the tiler starts, the certifier has to see the fire collars before the ceiling goes up. Mark those items on the checklist template as hold points, and every inspection started from it will stop there until a named person releases it.

  • Who can do this: anyone with “Manage templates”. Administrators hold it.
  • A SmarteBuild starter cannot be changed. Copy it first: it then appears under Your templates.
  1. Open Quality and choose the Templates tab.
  2. Under Your templates, click the template. Or press New template to start one, or Copy on a SmarteBuild starter.
  3. In the Items table, find the item. In its Point column choose Hold point or Witness point. Leave it on — for an ordinary item.
  4. Press Save template.

Every checklist started from this template from now on carries the marks. In the checklist the item shows “hold point” or “witness point”, and a hold point answered Pass offers Release hold point.

  • A checklist already started keeps the items it started with. Changing the template does not add or remove a hold point on it.
  • A hold point answered Fail fails the checklist, like any failed item. It does not need releasing.
  • A hold point can be answered N/A, and then needs no release.
  • A witness point never stops anything. Recording who witnessed it is optional.
  • The plan’s Checklist field tells you how many hold points the chosen checklist has, so you can check before a trade starts.